Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8549542

- Product Categories
- Friendly Links
Information Name: | Supply Forney Uniflame |
Published: | 2012-03-15 |
Validity: | 30 |
Specifications: | Forney Uniflame |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Forney Uniflame amplifier, Forney Uniflame flame amplifier, Forney Uniflame flame detector, Forney Uniflame detector, Forney Uniflame flame detector, Forney Uniflame flame sensor, Forney Uniflame flame relay, Forney Uniflame UV flame sensor, Forney Uniflame processor, Forney Uniflame infrared probe General Machinery International Trading (Shanghai) Co., Ltd. Special Agent United States Forney Uniflame amplifier, Forney Uniflame flame amplifier, Forney Uniflame flame detector, Forney Uniflame detector, Forney Uniflame flame detector, Forney Uniflame flame sensor, Forney Uniflame flame relay, Forney Uniflame UV flame sensor, Forney Uniflame processor, Forney Uniflame infrared probes. Forney PM-DR-6101E amplifier device is a stand-alone intelligent controller consists of two printed circuit board placed on the base of the lid (PCB) components. Which includes a combination of PCB power relays and input / output (I / O) interface software. Another PCB including microprocessors, stability, and signal processing electronics. The entire device can be installed on a separate device enclosure. Can be equipped with a flame detection probe are: IDD-II probe with infrared filter, IDD-IIU infrared sensor without filter, UV-4 probe, DR-6 IDD / UV probe. D furnace flame detector Uniflame 95 Series Overview: FORNEY UNIFLAME Series flame detector is a microprocessor-based design of flame detector, using a solid-state infrared sensor (IR), ultraviolet sensors (UV) and dual-sensor (IR UV). Detector with an internal flame relay are, and adjust the ON / OFF threshold value, so do not need a remote flame amplifier. UNIFLAME \ 95 series flame detector detectors FORNEY DPD both the principles and characteristics, can detect single or multiple burner flame burner operating conditions with or without the target. UNIFLAME \ 95 series flame detector generated by the target modulation amplitude (ie the flame flicker). In the detector set-up process, choose to produce the best flame ON / OFF modulation frequency resolution. Can be manually adjusted or automatically adjusted to select the appropriate modulation frequency and detector gain. UNIFLAME \ 95 Series detectors with automatic programming (self-learning) function; 21 kinds of flame flicker frequency selection; four optional programming file to store settings; also increased through the use of FORNEY user applications based WINDOWS95/98/NT software, remote communications capabilities. All UNIFLAME \ 95 detectors require 24VDC power supply, with a quick 12-pin connectors, electronic self-test function (no need for mechanical shutter). Detector with an 8-digit / letter LED display and four buttons, easy to observe the operating parameters and select the user settings. Applications: IR-type: includes an infrared flame sensor, this sensor is suitable for the case of fuel oil and coal. UV-type: includes a UV flame sensor, this sensor is suitable for gas and light oil fuel situation. DS-type: (dual sensor) including the above two kinds of infrared and ultraviolet flame sensor, this sensor is suitable for multi-fuel situation. Uniflame series above installation accessories: Mechanical accessories panel mounted flange (to) whether the detector is a direct glimpse of the installation or fiber optic installation, you need to use the panel mounting flange, plate flange mounted external interfaces to 1 "NPT female, material for the hard aluminum. universal joint (direct glimpse of type optional) detector of the universal joint, the detector is installed after the detector is used to adjust the viewing angle. insulating tube (direct glimpse of the type required) insulated pipe is prevent the heat from the heat reached the observation tube detector, the detector with the earth while the electrical insulation, and the corresponding observation tube together with the mounting flange ordered quartz window (direct glimpse of the type optional) quartz window, when the detector needs sealing or connection to use, quartz window, blocking the furnace pressure, hot gases and ash, so that contamination can not be close to the detector or the lens. Specifications US standard 1-inch taper thread. need to be sealed, use a 1 inch Three connections to pass cooling air. fiber optic components (optical type required) fiber optic components including catheter components, catheter components, fiber optic components, install the furnace wall components in the complex and multi-burner burner burning boilers, the use of fiber optic components can be flame "flash" signal to the furnace through the optical fiber transmission, the easy detection monitoring for electrical accessories detector cable FORNEY provide UNIFLAME \ 95 Series 12-detector-specific core foil fully shielded cable. This cable includes six # 18AWG and four # 22AWG wire, with one pair # 22AWG twisted pair. cable jacket is treated polyolefin materials (flame retardant, low smoke, zero halogen) Maximum diameter of 0.43 "(10.9mm). Each detector longest cable up to 1000 feet. This need for raw rubber cable quick connectors as described below. Quick connectors UNIFLAME \ 95 series comes with 12 factory detector core cable connector Yang, FORNEY provide matching cable female connector for easy field installation. Air plug attachment reference manual. With an adapter cable to provide the pre-FORNEY 12 core cable length can be scheduled, with a female connector factory. The attachment length range from 10 feet (3m) to 300 feet (91m). If you need a remote junction box component communication, and UNIFLAME detector and the distance between the control room over 200 feet (61M), then each detector must be connected to a junction box. In the junction box, two communication lines must be separated with 12-pin cable connected, in the circulation loop, the way to multi-point series (daisy chain) to each detector, and finally to the computer. FORNEY junction box assembly, the length ranges from 3-30 feet (0.9 to 9.1 meters), offers a convenient wiring. Junction box at one end of the quick connector to the UNIFLAME detector. FORNEY 12-core cable with factory installed quick connectors, flexible cable that connects to the junction box in the other, the terminals. Terminals can be connected 14AWG cable clamp with push-type connectors for quick secure connection. Through the junction box, the installer can connect all the wiring, but FORNEY 12-pin cable to reach the burner management system of the two lines are not connected. From the detector up and down two communication lines with the junction box must be connected to the final two core communication cable through to reach the computer. 24VDC power supply to provide 24VDC power FORNEY, for the 95 Series flame detectors. |
Admin>>>
You are the 31638 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai General Machinery Trading All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 31638 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai General Machinery Trading All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility